F520 |
F510 |
F420 |
F405 |
|
Differential pressure decay |
Differential pressure decay |
Standard pressure decay |
Standard pressure decay |
|
3 ranges of leak
measurement (DP)
Full scale :
50 Pa 500 Pa 5 000 Pa |
3 ranges of leak
measurement (DP)
Full scale :
50 Pa 500 Pa 5 000 Pa |
3 ranges of leak
measurement (DP)
Full scale :
50 Pa 500 Pa 5 000 Pa |
3 ranges of leak
measurement (DP)
Full scale :
50 Pa 500 Pa 5 000 Pa |
|
Test modes :
DP
DP/Dt
Flow units
Blocage test
Additional ones depending
on your applications |
Test modes :
DP
DP/Dt
Flow units
Blocage test
Additional ones depending
on your applications |
Test modes :
DP
DP/Dt
Flow units
Blocage test
Additional ones depending
on your applications |
Test modes :
DP
DP/Dt
Flow units
Blocage test
Additional ones depending
on your applications |
|
64 programs / head |
32 programs |
4 programs |
8 programs |
|
Manual calibration on front
panel using calibrated leak |
Manual calibration on front
panel using calibrated leak |
Manual calibration on front
panel using calibrated leak |
Manual calibration on front
panel using calibrated leak |
|
RS232 : P .C. and
configuration storage
module
RS485: ATEQ network |
RS232 : P .C. and
configuration storage
module
RS485: ATEQ network |
RS232 : P .C. and
configuration storage
module
|
RS232 : P .C. and
configuration storage
module
RS485: ATEQ network |
|
250 x 136x 367 |
426.5 x 194 x 108.5 |
250 x 136x 272 |
240 x 137 x 120.7 |
|
8 |
8 |
8 |
5 |
|
Navigation keys
LCD display 4 lines
Results indicator lights |
Navigation keys
LCD display 4 lines
Results indicator lights |
Navigation keys
LCD display 4 lines
Results indicator lights |
Results display
(Good part - cycle in progress - Bad part) |
|
24 V DC 1 .6 A
Main adapter
included (110-240 V AC) |
24 V DC 1 .6 A
Main adapter
included (110-240 V AC) |
24 V DC 1 .6 A
Main adapter
included (110-240 V AC) |
24 V DC / 1.25 A |
|
Clean and dry air required
Air quality standard to be
applied (ISO 8573-1) |
Clean and dry air required
Air quality standard to be
applied (ISO 8573-1) |
Clean and dry air required
Air quality standard to be
applied (ISO 8573-1) |
Clean and dry air required
Air quality standard to be
applied (ISO 8573-1) |
|
Operating : + 10°C to + 45°C
Storage : 0°C to + 60°C |
Operating : + 10°C to + 45°C
Storage : 0°C to + 60°C |
Operating : + 10°C to + 45°C
Storage : 0°C to + 60°C |
Operating : + 10°C to + 45°C
Storage : 0°C to + 60°C |
|
Electronic regulator
Dual pressure
High speed valve
Y valve: 2 test ports
2 pneumatic outputs for
control
of sealing connectors
6 x 24 V programmable
outputs for external
automation
2 analog outputs:
0 - 10V or 4 - 20mA
Automatic calibration check
Temperature compensation
Modbus (Field bus)
|
Electronic regulator
Dual pressure
High speed valve
Y valve: 2 test ports
2 pneumatic outputs for
control
of sealing connectors
6 x 24 V programmable
outputs for external
automation
2 analog outputs:
0 - 10V or 4 - 20mA
Automatic calibration check
Temperature compensation
Modbus (Field bus)
|
3 inputs/ 4 outputs
2 pneumatic outputs for
control
of sealing connectors
|
Remote control RC5 mini Accessories Case
Pneumatic kit (mechanical regulator + manometer + pipe cutter + couplings...)
|